Search results for " Lens"
showing 10 items of 510 documents
First M87 Event Horizon Telescope Results. II. Array and Instrumentation
2019
The Event Horizon Telescope (EHT) is a very long baseline interferometry (VLBI) array that comprises millimeter- and submillimeter-wavelength telescopes separated by distances comparable to the diameter of the Earth. At a nominal operating wavelength of ~1.3 mm, EHT angular resolution (λ/D) is ~25 μas, which is sufficient to resolve nearby supermassive black hole candidates on spatial and temporal scales that correspond to their event horizons. With this capability, the EHT scientific goals are to probe general relativistic effects in the strong-field regime and to study accretion and relativistic jet formation near the black hole boundary. In this Letter we describe the system design of th…
Positive density-dependent growth supports costs sharing hypothesis and population density sensing in a manipulative parasite.
2017
SUMMARYParasites manipulate their hosts’ phenotype to increase their own fitness. Like any evolutionary adaptation, parasitic manipulations should be costly. Though it is difficult to measure costs of the manipulation directly, they can be evaluated using an indirect approach. For instance, theory suggests that as the parasite infrapopulation grows, the investment of individual parasites in host manipulation decreases, because of cost sharing. Another assumption is that in environments where manipulation does not pay off for the parasite, it can decrease its investment in the manipulation to save resources. We experimentally infected rainbow trout Oncorhynchus mykiss with the immature larva…
The utility of measuring tear film break-up time for prescribing contact lenses.
2017
Abstract Purpose To evaluate the clinical value of non-invasive keratograph tear film breakup time (NIKBUT) in the assessment of pre-corneal and pre-lens tear film quality for prescribing contact lenses (CLs). Methods Forty-six subjects aged 25.5 ± 4.3 (mean ± standard deviation) years were recruited. Visual acuity (VA), anterior eye health checks and NIKBUT were evaluated. On the following day, subjects were fitted with a daily Silicon Hydrogel (SiHy) CL in one eye and a Hydrogel (Hy) CL in the other. After four hours one material for both eyes was chosen based on a qualitative analysis which included VA, CL fitting and comfort. Information about the first and the mean NIKBUT was then cont…
Accuracy of five intraocular lens formulas in eyes with trifocal lens implant.
2020
Accuracy of intraocular lens (IOL) calculation formulas SRK/T, Hoffer Q, Holladay 1, Haigis and Barrett Universal II were compared in prediction of postoperative refraction for multifocal and implants using a single optical biometry device. The authors included 88 refractive lens exchange and cataract surgeries, with AcrySof IQ PanOptix implant (Alcon Laboratories, Inc.). All eyes were divided into three groups based on axial length (AL), group 1: 24.5 mm (6 eyes). The refractive prediction error (RPE) and mean absolute error (MAE) were calculated for 5 different formulas: SRK/T, Hoffer Q, Holladay 1, Haigis and Barrett Universal II. For eyes with the AL between 22 mm and 24.5 mm the greate…
Objective Assessment of Nuclear and Cortical Cataracts through Scheimpflug Images: Agreement with the LOCS III Scale.
2016
Purpose To assess nuclear and cortical opacities through the objective analysis of Scheimpflug images, and to check the correlation with the Lens Opacity Classification System III (LOCS III). Methods Nuclear and cortical opacities were graded according to the LOCS III rules after pupil dilation. The maximum and average pixel intensity values along an elliptical mask within the lens nucleus were taken to analyse nuclear cataracts. A new metric based on the percentage of opaque pixels within a region of interest was used to analyse cortical cataracts. The percentage of opaque pixels was also calculated for half, third and quarter areas from the region of interest’s periphery. Results The maxi…
Effect of contact lens surface properties on comfort, tear stability and ocular physiology.
2018
Aim: Retrospective analysis of different contact lens wearing groups suggests lens surface lubricity is the main factor influencing contact lens comfort. However, the examined commercially available contact lenses differ in material and design as well as surface properties. Hence this study isolates the contribution of lens surface properties using an ultra-thin coating technology. Methods: Nineteen habitual contact lens wearers (21.6. ±. 1.7years) wore formofilcon B soft monthly disposable contact lenses with and without coating technology modified surface properties for a month each in a randomised double-masked cross-over study. Objective non-invasive: breakup time (NIKBUT), NIKBUT avera…
Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity
2018
Aim To evaluate the repeatability of an optical device for measuring the Zernike coefficients of toric intraocular lenses (IOLs) and assess whether its toricity has any impact in its repeatability. Methods An experienced technician used the NIMO TR1504 to measure the Zernike coefficients 30 times for an aperture of 4.50 mm for all lenses included. The IOLs included were divided into two group: toric and non-toric ones. The cylindrical powers of the toric lenses included in the present study were 1.00, 1.50, 2.25, 3.00 and 3.75 D. Finally, the repeatability of the NIMO TR1504 was described in terms of within subject standard deviation (Sw) and repeatability limit. Results The Sw was smaller …
The contribution of tear osmolarity measurement to ocular surface assessment in contact lens wearers
2012
Purpose: To determine whether tear osmolarity using the TearLabTM Osmolarity System contributes to the assessment of the ocular surface in contact lens (CL) wearers.Methods: Data were collected from 44 CL wearers (28 tolerant and 16 intolerant) and 34 healthy subjects. Every patient underwent a thorough ophthalmic examination and tear osmolarity test, conjunctival impression cytology and meibomian lipid sampling. Symptoms, break-up time (BUT), tear osmolarity, conjunctival expression of HLA-DR and meibomian fatty acid composition were evaluated.Results: Tear osmolarity was significantly higher in the controls compared to tolerant and intolerant CL wearers (p=0.0007). Flow cytometry results …
Accommodative response in various design soft contact lens wearers
2021
The progression of myopia in young adults due to inadequate accommodation is currently one of the global research challenges. Studies have demonstrated that multifocal contact lenses have a different effect on accommodative response. The aim of this study was to assess the accommodative lag using various design multifocal contact lenses at different working distances. The study was conducted on 10 emmetropic subjects aged 22â28 years. An open-field autorefractor PowerRef 3 was used to assess the response of eye accommodation to stimuli placed at a distance of 25 cm and 40 cm for subjects wearing monofocal and multifocal contact lenses. To determine the effectiveness of contact lens design f…
Impact of viewing distance on relative depth judgements for stimuli in physical space
2019
In natural viewing, numerous depth cues are available to the visual system, but their significance varies considerably depending on the viewing distance. How is it reflected in the outcome of depth judgements? We have designed a psychophysical experiment with a limited number of depth cues to examine distance-related changes in the correct response rate and time. Twenty young adults evaluated relative depth of stimuli in physical space. Each time four constant angular size achromatic stimuli were presented on a volumetric multi-planar display. One of these stimuli was demonstrated closer to the observer comparing to others. The experiment followed the four-interval forced-choice procedure. …